Mandatory Replacement Years for Home Heat Tanks

 

Mandatory Replacement Years for Home Heat Tanks (calculated from the year of manufacture)
Steel Thickness Outlet/Connection Type Mandatory Replacement Year
Non-metallic tanks Not applicable No mandatory replacement year
Double-bottom metallic tank Not applicable No mandatory replacement year
Metallic tank with nominal
steel thickness of 2.0 mm
Tank end or top burner connection 15 years from year
of tank manufacture
Metallic tank with nominal
steel thickness of 2.0 mm
Bottom outlet burner connection 20 years from year
of tank manufacture
Metallic tank with nominal
steel thickness of 2.3 mm
Tank end or top burner connection 20 years from year
of tank manufacture
Metallic tank with nominal
steel thickness of 2.3 mm
Bottom outlet burner connection 25 years from year
of tank manufacture